Manual – Xylem MJK 713 Open Channel Flowmeter User Manual.
Page 32. US 3.10 713 Flow Converter 1210 - Sw 833062. MJK North America, Inc. 37 Sherwood Terrace, #126 Lake Bluff, Il 60044 Tel.: 847-482-8655 Fax: 847-482-8654 mjkusa@mjk.com www.mjk.com. Appendix C Technical specifications.

Dimensions and accessories. (order no. 200205) Sensor bracket, standard. (order no. 200220) Sensor bracket, short.

(order no. 200219) Flume mounting bracket. (Max. width 21.7 in: order no. 202020 / max. width 37.4 in: order no. 202021). Ultrasonic Sensor - one year warranty. 0 - 1 ft., 0 - 3 ft., 0 - 10 ft.

Dia. 4.06 ", height 4.17 " vAloX (reg. tm of General electric Co.) Shielded, oil resistant PUr insulation, length 39 ft. Can be extended to 150 ft. using MJK 690010 cable. neMA 6P, waterproof, withstands submersion up to 30 ft. FM Class 1 Division 1 Groups A-G. Ce en50081-1, en50082-1.

Model 3400 Hydrostatic Level Transmitter - 1 year warranty. temp. deviation, zero point: Better than ± 0.01 % / °F temp. deviation, full range: Better than ± 0.005 % / °F linearity / Stability: Better than ± 0.5 % FS. Better than ± 0.1 % FS @ 50 to 85 °F. Better than ± 0.2 % FS @ full temperature range. long time stability:

Better than ± 0.1% FS per year. Diaphragm: 99.9 % Al. Measurement cell packing: viton. 10 - 30 v DC (12 - 30 v DC for cable lengths above 315 ft.) two-wire 4 - 20 mA (passive transmitter) 2 ? AwG 20, shielded, oil resistant PUr insulation. 39 ft. longer cable lengths available, consult the factory. withstands a static pressure equal to max. measuring range. Class 1 Division 1 Groups A-D and AteX ex ia IIC t6.

Ce en50081-1, en50082-1. Can be delivered with other cable lengths on request. 713 Series Open Channel Flowmeter. 0 - 1 ft., 0 - 3 ft., 0 - 10 ft. or custom ranges. Height 7.28 “, width 9.45 “, depth 4.53 “ 110 - 120 v AC, power consumption max. 10 w. ? 0.2 % of adjusted range.

Polystyrene (housing and cover) either from ultrasonic sensor or from hydrostatic level. or other (0)4 - 20 mA signal. relay no. 1-4, max. 250 v, max. 4 A resistive / max.

100 w inductive load. Selectable as alarm, counter, flow > 0 or sampler output. terminal 19 - 20: totalizer output (optocoupler), max. 36 v AC/DC, 50 mA, one shot, programmable from 100 ms to 10 s. terminal 21 - 22: (0)4-20 mA, max. 500 ohm loop resistance, galvanically isolated.

Standard formulas according to AStM standards and. US Department of the Interior. optional formula Q = C ? hx. 10 point level to flow curve linearization. 2 ? 24 character backlit lCD display for reading and.